Mitsubishi Electric Q26UD(E)HCPU User Manual page 529

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
Meaning
SD243
No. of base
slots
SD244
SD243
No. of base
slots
No. of base
slots
(Operation
SD244
status)
SD245
No. of base
slots
(Mounting
SD246
status)
Loaded
Loaded
SD250
maximum
maximum I/O
I/O
No
Number of
SD254
mounted
modules
SD255
I/O No.
Network
SD256
No.
Group
SD257
number
MELSECN
Station
SD258
ET/10,
No.
MELSECN
Standby
ET/H
SD259
informatio
information
n
SD260
Information
to
from 2nd
SD264
module
SD265
Information
to
from 3rd
SD269
module
SD270
Information
to
from 4th
SD274
module
Explanation
• The number of base unit slots set in parameter is stored.
When the number is not set in parameter, the number of
base unit slots used is stored.
b15 to b12 b11 to b8 b7 to b4 b3 to b0
SD243
Extension 3 Extension 2
Extension 1
SD244
Extension 7 Extension 6
Extension 5
• For the Q00UJCPU, the bits for the third to seventh
extension bases are fixed to "0".
• For the Q00UCPU, Q01UCPU, and Q02UCPU, the bits for
the fifth to seventh extension bases are fixed to "0".
The number of slots used is stored in the area corresponding
to each base unit as shown below. (The number of slots set in
the parameter setting.)
b15 to b12 b11 to b8 b7 to b4 b3 to b0
SD243
Extension 3 Extension 2
Extension 1
Fixed to 0
Fixed to 0
Fixed to 0
SD244
The number of slots where modules are actually mounted is
stored in the area corresponding to each base unit as shown
below.
b15 to b12 b11 to b8 b7 to b4 b3 to b0
Extension 3 Extension 2
Extension 1
SD245
SD246
Fixed to 0
Fixed to 0
Fixed to 0
When SM250 is turned on from off, the first two digits of the
number, which is the last I/O number of the mounted modules
plus 1, are stored.
The value obtained by adding 1 to the end I/O number of a
mounted module and dividing by 16 is stored.
Example 1:End I/O number 010F SD250 = 0011
Example 2:End I/O number 0FFF SD250 = 0100
Indicates the number of mounted MELSECNET/10 modules or
MELSECNET/H modules.
Indicates the I/O number of mounted MELSECNET/10 module
or MELSECNET/H module.
Indicates the network No. of mounted MELSECNET/10
module or MELSECNET/H module.
Indicates the group No. of mounted MELSECNET/10 module
or MELSECNET/H module.
Indicates the station No. of mounted MELSECNET/10 module
or MELSECNET/H module.
In the case of standby stations, the module number of the
standby station is stored. (1 to 4)
Data configuration is the same as that of the 1st module
(SD255 to SD259).
Data configuration is the same as that of the 1st module
(SD255 to SD259).
Data configuration is the same as that of the 1st module
(SD255 to SD259).
Corresponding
Set by
(When Set)
Main
Extension 4
S (Initial)
Main
Extension 4
Main
Extension 4
S (Request
END)
S (Initial)
H
H
S (Initial)
APPENDICES
Corresponding
ACPU
CPU
D9
Qn(H)
QnPH
QnPRH
QnU
New
Q00J/Q00/Q01
*1
Q00J/Q00/Q01
Qn(H)
QnPH
QnPRH
New
Q00J/Q00/Q01
QnU
LCPU
QCPU
New
Qn(H)
QnPH
QnPRH
*2
QnU
Qn(H)
QnPH
QnPRH
*3
QnU
527
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents