Mitsubishi Electric Q26UD(E)HCPU User Manual page 465

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
OFF: Continuous
Presence/absence
of continuous
SM323
transition for entire
ON: Continuous
block
OFF: When transition is
Continuous
SM324
transition
ON: When no
prevention flag
Output mode at
OFF: OFF
SM325
block stop
ON: Preserves
SFC device clear
OFF: Clear device
SM326
mode
ON: Preserves device
OFF: Hold step output
Output during end
SM327
step execution
ON: Hold step output
OFF: Clear processing
Clear processing
SM328
mode when end
ON: Clear processing
step is reached
Online change
OFF: Not executed
SM329
(inactive block)
ON: Being executed
status flag
Meaning
Explanation
transition not
Set the presence/absence of continuous
effective
transition for the block where
"Continuous transition bit" of the SFC
transition
data device has not been set.
effective
• This relay is off while the module is in
the continuous transition mode or
during continuous transition, and is on
executed
when continuous transition is not
executed.
transition
• This relay is always on while the CPU
module is operating not in the
continuous transition mode.
Select whether the coil outputs of the
active steps are held or not at the time of
a block stop.
• The initial value is set to off when the
output mode at a block stop is off in the
parameter setting, and it is set to on
when the coil outputs are set to be
held.
• When this relay is turned off, all coil
outputs are turned off.
• When this relay is turned on, the coil
output state is held.
Select the device status at the time of
switching from STOP to program write,
and then to RUN. (All devices except the
step relay)
turned OFF
If this relay is off, the coil output turns off
(cleared)
when the step held after transition (SC,
SE, or ST) reaches the end step.
held
Select whether clear processing will be
performed or not if active steps other than
the ones being held exist in the block
when the end step is reached.
• When this relay turns OFF, all active
steps are forcibly terminated to
is performed.
terminate the block.
• When this relay is ON, the execution of
is not performed.
the block is continued as-is.
• If active steps other than the ones
being held do not exist when the end
step is reached, the steps being held
are terminated to terminate the block.
This relay is on while online change
(inactive block) is executed.
Corresponding
Set by
Corresponding
ACPU
(When Set)
M9
Q00J/Q00/Q01
U
M9103
Q00J/Q00/Q01
S
(Instruction
M9104
execution)
Q00J/Q00/Q01
S (Status
New
change)
Q00J/Q00/Q01
S (Initial)/U
M9196
Q00J/Q00/Q01
U
New
S (Initial)/U
New
U
Q00J/Q00/Q01
Q00J/Q00/Q01
U
New
S (Status
New
L06/L26/L26CPU-
change)
APPENDICES
A
CPU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
Qn(H)
QnPH
QnPRH
QnU
LCPU
Qn(H)
QnPH
QnPRH
QnU
LCPU
*1
*1
QnU
LCPU
*8
QnU
*11
BT
463