Number
Name
SM1563
SM1564
SM1565
SM1566
SM1567
SM1568
SM1569
SM1570
SM1571
SM1572
Data tracking
OFF: No trigger
transfer trigger
SM1573
ON: Trigger
specification
SM1574
SM1575
SM1576
SM1577
SM1578
SM1579
SM1580
SM1581
SM1582
SM1583
OFF: System switching
System switching
enable/disable
SM1590
flag from network
ON: System switching
module
ON: Error is not
Standby system
error detection
SM1591
disable flag at
OFF: Error is detected
system switching
OFF: Disable user
Enable/disable
SM1592
user system
ON: Enable user
switching
Setting to access
extension base
OFF: Error
SM1593
unit of standby
ON: Ignored
system CPU
OFF: Start memory
Memory copy to
SM1595
other system
ON: No memory copy
start flag
Meaning
SM1563
Block 44
SM1564
Block 45
SM1565
Block 46
SM1566
Block 47
SM1567
Block 48
SM1568
Block 49
SM1569
Block 50
SM1570
Block 51
SM1571
Block 52
SM1572
Block 53
SM1573
Block 54
SM1574
Block 55
SM1575
Block 56
SM1576
Block 57
SM1577
Block 58
SM1578
Block 59
SM1579
Block 60
SM1580
Block 61
SM1581
Block 62
SM1582
Block 63
SM1583
Block 64
Turns on when a system switching request is
request issuing
issued from the network module. The module
module absent
that issued the request can be checked in
SD1590.
request issuing
Turns off when all bits of SD1590 are off.
module present
This flag is used when switching the system
in any of the following sources to determine
detected by new
whether to detect "STANDBY" (error code
standby system
6210) in the new standby system:
at system
[Reason(s) for system switching]
switching
• System switching with a programming tool
• System switching using dedicated
by new standby
instruction
system at system
• System switching by the intelligent function
switching
module
This relay stores whether to enable manual
system switching
switching using a programming tool or the
system switching instruction (SP.CONTSW).
system switching
This relay sets the behavior of the system
after the standby CPU in the separate mode
accessed the buffer memory of an intelligent
function module mounted on an extension
base unit.
• OFF: "OPERATION ERROR" (error code:
4112) is returned.
• ON: No processing
When SM1595 is turned on from off, memory
copying from the control system to the
standby system starts. Note that memory
copy
copy does not start even after SM1595 was
turned on from off if the I/O No. of the copy
initiated
destination (standby system CPU module:
3D1
) is not stored in SD1595.
H
Set by
Explanation
(When Set)
• When data is
transferred based
on the tracking
setting of the
Redundant
parameter window,
the target block is
specified as
trigger.
• When "Do auto
forward Tracking
block No.1" is
selected for the
S (Initial)/U
tracking setting,
SM1520 is turned
on by the system
at power-on or
when the system
is switched from
STOP to RUN. In
other cases,
SM1520 to
SM1583 are
turned on by the
user.
S (Every
END
processing)
APPENDICES
Corresponding
Corresponding
ACPU
CPU
M9
New
QnPRH
New
QnPRH
U
New
QnPRH
U
New
QnPRH
U
New
QnPRH
U
New
QnPRH
A