(1) Diagnostic information
Number
Name
OFF: No error
SM0
Diagnostic errors
ON: Error
Self-diagnostic
OFF: No error
SM1
error
ON: Error
OFF: No error common
Error common
SM5
information
ON: Error common
OFF: No error
Error individual
SM16
information
ON: Error individual
OFF  ON:Error clear
SM50
Error reset
OFF: Normal
SM51
Battery low latch
ON: Battery low
OFF: Normal
SM52
Battery low
ON: Battery low
Meaning
Explanation
• This relay turns on if an error is
detected by diagnostics. (Also turns on
if an error is detected by an
annunciator or the CHK instruction.)
• This relay remains on even after the
system returns to normal.
• This relay turns on if an error is
detected by diagnostics. (Also turns on
if an error is detected by an
annunciator.)
• This relay remains on even after the
system returns to normal.
• This relay turns on if an error is
detected by self-diagnostics. (Remains
off if an error is detected by an
annunciator or the CHK instruction.)
• This relay remains on even after the
system returns to normal.
• This relay turns on if an error is
detected by self-diagnostics. (Remains
off if an error is detected by an
annunciator.)
• This relay remains on even after the
system returns to normal.
This relay turns on if error common
information
information data exists when SM0 turns
on.
information
individual
This relay turns on if error individual
information
information data exists when SM0 turns
on.
information
Conducts error reset operation
• This relay turns on if the battery voltage
of the CPU module or the memory card
drops below the rated value.
• This relay remains on even after the
battery voltage returns to normal.
• The on/off timing is synchronized with
that of the BAT. LED.
• This relay turns on if the battery voltage
of the CPU module drops below the
rated value.
• This relay remains on even after the
battery voltage returns to normal.
• The on/off timing is synchronized with
that of the BAT. LED.
• This relay turns on if the battery voltage
of the CPU module drops below the
rated value.
• This relay remains on even after the
battery voltage returns to normal.
• The on/off timing is synchronized with
that of the ERR. LED.
This relay has the same specifications as
those of SM51 except that this relay turns
off after the battery voltage returns to
normal.
Corresponding
Set by
Corresponding
ACPU
(When Set)
M9
S (Error)
New
Q00J/Q00/Q01
M9008
S (Error)
Q00J/Q00/Q01
New
S (Error)
New
S (Error)
New
U
New
M9007
S (Error)
New
New
Q00J/Q00/Q01
S (Error)
M9006
APPENDICES
A
CPU
Qn(H)
QnPH
QnPRH
QnU
LCPU
Qn(H)
QnPH
QnPRH
QnU
LCPU
QCPU
LCPU
QCPU
LCPU
QCPU
LCPU
Qn(H)
QnPH
QnPRH
QnU (except
QnUDV)
QnUDV
LCPU
QCPU
LCPU
455

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents