Mitsubishi Electric Q26UD(E)HCPU User Manual page 504

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
CH2
coincidence
Resets CH2 counter
SM1910
signal No.1
value coincidence No.1.
reset command
CH2
coincidence
Resets CH2 counter
SM1911
signal No.2
value coincidence No.2.
reset command
CH2
Controls outputs from
coincidence
SM1912
CH2 coincidence output
output enable
No.1 and No.2 terminals.
command
CH2 preset
Presets the counter
SM1913
command
value.
CH2 count down
SM1914
Counts down pulses.
command
CH2 count
SM1915
enable
Starts counting.
command
CH2 counter
function
Starts the selected
SM1916
selection start
counter function.
command
CH2 external
preset (phase Z)
Resets CH2 external
SM1917
request
preset (phase Z) request
detection reset
detection.
command
CH2 pulse
Starts pulse
SM1918
measurement
measurement.
start command
CH2 error reset
SM1919
Resets the CH2 error.
command
502
Meaning
• This relay is turned on to reset CH2
counter value coincidence No.1.
• The command is valid while this relay is
on.
• The on time must be held for at least 2ms.
• This relay is turned on to reset CH2
counter value coincidence No.2.
• The command is valid while this relay is
on.
• The on time must be held for at least 2ms.
• This relay is turned on to perform
coincidence output from CH2 coincidence
output No.1 and CH2 coincidence output
No.2 terminals.
• The command is valid while this relay is
on.
• This relay is turned on to preset the
counter value.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
• This relay is turned on to count down
pulses.
• The command is valid while the Pulse
input mode is either 1-phase multiple of n
or 1-phase multiple of n (A phase only).
• The command is valid while this relay is
on.
• This relay is turned on to start counting.
• The command is valid while this relay is
on.
• This relay is turned on to start the
selected counter function.
• When the count disabling function is
selected, the command is valid while this
relay is on.
• When the latch counter function or the
sampling counter function is selected, the
command is valid at the rise of this relay
(off  on). The on time must be held for
at least 2ms.
• When the count disabling/preset function
or the latch counter/preset function is
selected, the command is invalid.
• This relay is turned on to reset CH2
external preset (phase Z) request
detection.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
• This relay is turned on to measure pulses.
• The command is valid while this relay is
on.
• This relay is turned on to reset the CH2
error.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
Explanation
(When Set)
Corresponding
Set by
Corresponding
ACPU
M9
U
New
U
New
U
New
U
New
U
New
U
New
U
New
U
New
U
New
U
New
CPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU