Number
Name
SM90
SM91
SM92
SM93
Startup of
OFF: Not started
monitoring timer for
SM94
step transition
(Enabled only
ON: Started
SM95
when SFC
program exists)
SM96
SM97
SM98
SM99
Serial
OFF: Not to be used
SM100
communication
ON: To be used
function using flag
OFF: Other than MC
Communication
SM101
protocol status flag
ON: MC protocol
OFF: Normal
SM110
Protocol error
ON: Error
Communication
OFF: Normal
SM111
status
ON: Error
Error information
SM112
ON: Cleared
clear
OFF: Normal
SM113
Overrun error
ON: Error
OFF: Normal
SM114
Parity error
ON: Error
OFF: Normal
SM115
Framing error
ON: Error
Meaning
Explanation
Corresponds to
SD90
Corresponds to
SD91
Corresponds to
SD92
Corresponds to
SD93
Corresponds to
(monitoring timer
SD94
reset)
Corresponds to
(monitoring timer
SD95
started)
Corresponds to
SD96
Corresponds to
SD97
Corresponds to
SD98
Corresponds to
SD99
This relay stores whether the serial
communication function is set to be used
or not in PLC parameter.
protocol
communication
This relay stores whether the
devices
communication-target device is an MC
protocol communication device or not.
communication
device
• Turns on if a failed protocol was used
to make communication in the serial
communication function.
• This relay remains on even after the
protocol returns to normal.
• Turns on if the mode used to make
communication was different from the
mode set in the serial communication
function.
• This relay remains on even after the
system returns to normal.
This relay is turned on to clear error
codes stored in SM110, SM111, SD110,
and SD111. The error codes are cleared
when this relay is turned on.
This relay turns on if an overrun error
occurs in communication using the serial
communication function.
This relay turns on if a parity error occurs
in communication using the serial
communication function.
This relay turns on if a flaming error
occurs in communication using the serial
communication function.
Set by
(When Set)
• Goes ON when
measurement of
step transition
monitoring timer is
commenced.
U
• Resets step
transition monitoring
timer when it goes
OFF.
S (Power-on
or reset)
S (Being
communicat
ed via RS-
232 or RS-
422/485)
S (Error)
S (Error)
U
S (Error)
S (Error)
S (Error)
APPENDICES
Corresponding
Corresponding
ACPU
CPU
M9
M9108
M9109
M9110
M9111
M9112
Qn(H)
QnPH
QnPRH
M9113
M9114
New
New
New
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
Q00/Q01
*2
New
QnU
*3
LCPU
457