Mitsubishi Electric Q26UD(E)HCPU User Manual page 502

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
OFF: No error
SM1887
CH1 error
ON: Error
OFF: No warning
SM1888
CH1 warning
ON: Warning
CH1
coincidence
Resets CH1 counter
SM1890
signal No.1
value coincidence No.1.
reset command
CH1
coincidence
Resets CH1 counter
SM1891
signal No.2
value coincidence No.2.
reset command
CH1
Controls outputs from
coincidence
SM1892
CH1 coincidence output
output enable
No.1 and No.2 terminals.
command
CH1 preset
Presets the counter
SM1893
command
value.
CH1 count down
SM1894
Counts down pulses.
command
CH1 count
SM1895
enable
Starts counting.
command
CH1 counter
function
Starts the selected
SM1896
selection start
counter function.
command
CH1 external
preset (phase Z)
Resets CH1 external
SM1897
request
preset (phase Z) request
detection reset
detection.
command
500
Meaning
• This relay turns on if the CH1 error
occurs.
• This relay turns off when an error cause is
removed and CH1 error reset command is
turned on.
• This relay turns on if a warning occurs in
CH1.
• This relay turns off when a warning cause
is removed and CH1 error reset command
is turned on.
• This relay is turned on to reset CH1
counter value coincidence No.1.
• The command is valid while this relay is
on.
• The on time must be held for at least 2ms.
• This relay is turned on to reset CH1
counter value coincidence No.2.
• The command is valid while this relay is
on.
• The on time must be held for at least 2ms.
• This relay is turned on to perform
coincidence output from CH1 coincidence
output No.1 and CH1 coincidence output
No.2 terminals.
• The command is valid while this relay is
on.
• This relay is turned on to preset the
counter value.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
• This relay is turned on to count down
pulses.
• The command is valid while the Pulse
input mode is either 1-phase multiple of n
or 1-phase multiple of n (A phase only).
• The command is valid while this relay is
on.
• This relay is turned on to start counting.
• The command is valid while this relay is
on.
• This relay is turned on to start the
selected counter function.
• When the count disabling function is
selected, the command is valid while this
relay is on.
• When the latch counter function or the
sampling counter function is selected, the
command is valid at the rise of this relay
(off  on). The on time must be held for
at least 2ms.
• When the count disabling/preset function
or the latch counter/preset function is
selected, the command is invalid.
• This relay is turned on to reset CH1
external preset (phase Z) request
detection.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
Explanation
(When Set)
S (Every
processing)
S (Every
processing)
Corresponding
Set by
Corresponding
ACPU
M9
END
New
END
New
U
New
U
New
U
New
U
New
U
New
U
New
U
New
U
New
CPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU
LCPU