Error code
Error item
(Hexadecimal)
iQ Sensor
C055
Solution related
H
error
iQ Sensor
C056
Solution related
H
error
iQ Sensor
C059
Solution related
H
error
iQ Sensor
C05C
Solution related
H
error
iQ Sensor
C061
Solution related
H
error
MELSOFT
connection
C080
extended
H
setting related
error
MELSOFT
connection
C086
extended
H
setting related
error
446
Error details
System error
System error
The function not supported by the target device
supporting iQ Sensor Solution was executed.
• The communication setting value is out of the
range.
• The communication setting item not supported
by the target device supporting iQ Sensor
Solution is set.
• The setting item required for the target device
supporting iQ Sensor Solution is not set.
System error
The target IP address is not obtained in
MELSOFT connection extended setting.
A received message exceeds the receptible size.
Corrective action
• Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
• Check the connection status of each Ethernet
cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and devices supporting
iQ Sensor Solution, and execute the function
again.
• If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
• Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
• Check the connection status of each Ethernet
cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and devices supporting
iQ Sensor Solution, and execute the function
again.
• If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
Check the version of the device supporting iQ
Sensor Solution.
Review the settings, and execute the function
again.
• Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
• Check the connection status of each Ethernet
cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and devices supporting
iQ Sensor Solution, and execute the function
again.
• If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
Set the station number <-> IP information to the
CPU module.
Correct the size of the send message of request
source.
Corresponding
CPU
QnUDV
LCPU
QnUDV
LCPU
QnUDV
LCPU
QnUDV
LCPU
QnUDV
LCPU
QnUDV
QnUDV