A-20
A-20
General Description
An AUTHORIZATION CODE is a numerical code dialed by station users (up to 10 digits), which will
override the station CLASS OF SERVICE - INDIVIDUAL [C-15] for facility access restriction.
(Series 6300 software enhancement) When a wrong code is received from a station/trunk, detailed
information on the unauthorized user is output as a System Message. This feature is called Toll Fraud
Report.
Operating Procedure
Choose one of the following procedures for entering an AUTHORIZATION CODE in the system database.
Procedure 1
Without an ACCOUNT CODE [A-18]:
1.
Lift the handset and receive Dial Tone.
2.
Enter the feature Access Code and receive Service Set Tone.
3.
Enter the AUTHORIZATION CODE (up to 10 digits).
4.
Receive Dial Tone.
5.
Enter the number to be called.
Note:
The feature access code for AUTHORIZATION CODE will be a maximum of three digits.
With an ACCOUNT CODE [A-18]:
1.
Lift the handset and receive Dial Tone.
2.
Enter the feature Access Code and receive Service Set Tone.
3.
Enter the AUTHORIZATION CODE and receive second Service Set Tone.
4.
Enter the ACCOUNT CODE [A-18] and receive Dial Tone.
5.
Enter the number to be called.
Procedure 2 (only for LEAST COST ROUTING [L-5] calls)
Without an ACCOUNT CODE [A-18]:
1.
Lift the handset and receive Dial Tone.
2.
Enter the number to be called.
3.
If an AUTHORIZATION CODE is required, the caller will receive SPDT.
4.
If SPDT is received, enter the AUTHORIZATION CODE (up to 10 digits) or the call is denied.
With an ACCOUNT CODE [A-18]:
1.
Lift the handset and receive Dial Tone.
2.
Enter the feature access code for the ACCOUNT CODE [A-18] and receive Service Set Tone.
3.
Enter the ACCOUNT CODE [A-18] and receive Dial Tone.
4.
Enter the number to be called.
5.
If AUTHORIZATION CODE is required, the caller will receive SPDT.
6.
If SPDT is received, enter AUTHORIZATION CODE (up to 10 digits) or the call is denied.
Note:
The feature access code for ACCOUNT CODE will be a maximum of three digits.
7.
The maximum number of digits in an AUTHORIZATION CODE is 10.
8.
The maximum number of AUTHORIZATION CODES is at least:
IMG, IMGx:
IMGxh, IMGdxh, MMG, UMG:
Page 26

Authorization Code

Authorization Code
500
4000
NEAX2400 ICS Business Features and Specifications