UNIVERGE SV8100/SV8300
6.3
System Hardware Manual
6.2.2
Power Supply Consumption
AC 100 V power supply:
Chassis
Controlling Chassis
Controlling Chassis + Expansion
Chassis
Controlling Chassis + 2 Expansion
Chassis
Controlling Chassis + 3 Expansion
Chassis
AC 200 V power supply:
Chassis
Controlling Chassis
Controlling Chassis + Expansion
Chassis
Controlling Chassis + 2 Expansion
Chassis
Controlling Chassis + 3 Expansion
Chassis
Environmental Conditions
6.3.1
Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, CD-8DLCA, CD-16DLCA, PZ-8DLCB
Operating Temperature: +32°F ~ +104
Recommended Long Term Temperature: -4°F ~ +140°F
(20°C ~ 60°C)
Table 3-14 Power Consumption
Maximum
RMS
Current
0.7A
2.89A
5.08A
7.2A
Table 3-15 Power Consumption
Maximum
RMS
Current
0.42A
1.49A
2.56A
3.63A
Issue No. 1.5
Watts Used
Watts Used
(Idle)
(Maximum)
40W
45W
136W
175W
232W
305W
328W
435W
Watts Used
Watts Used
(Idle)
(Maximum)
37W
42W
133W
172W
229W
302W
325W
432W
o
o
o
F (0
C ~ 40
C)
3 - 19