External Paging And Door Box; External; Door Box /External Page Relay Contacts; Connecting A Contact Relay Device To A Door Box/External - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue No. 1.5
E
S
6
XTERNAL
ECTION
6.1
6.2
10 - 16
P
AGING AND
External Page Relays
Two external dry contact relays are available when a PGD(2)-U( ) ADP is
installed which can be used to activate ancillary devices (i.e. door unlock
devices). The CD-CP00-AU also provides one page relay. When the relay on
the PGD(2)-U( ) ADP is used, there is no need to assign the relay to the Door
Box – connect the relay as detailed in the steps below for the Door Box used.
The relays on the PGD(2)-U( ) ADPs are numbered 5-8. Each Door Box/
external page circuit provides a dry relay contact.
If Relays 5 and 6 of a PGD(2)-U( ) ADP are set as
General Purpose Relays, then those relays cannot be
used for Door Box/Page Relays.
Program 10-21-05 sets the relay switch on the
CD-CP00-AU.
If General Purpose Relay set to 1 (Relay #1), the page
relay will not function on the CD-CP00-AU. General
Purpose Relays override Paging Relays and the Paging
Relay is associated with Relay #1 on CN100.
The service codes indicated are the default codes. Refer to Program
11-12-20 and 11-12-50 to redefine these codes as needed.

Door Box /External Page Relay Contacts

6.2.1
Connecting a Contact Relay Device to a Door Box/External Page
Relay
To connect a dry contact relay device to a Door Box/External Page
Relay:
To connect to the CD-CP00-AU:
1.
Connect an RCA line from the CN8 or CN9 connector on the
CD-CP00-AU to the appropriate location on the extension cross-
connect block.
2.
Connect the two-conductor station cable from the cross-connect
block to the external relay.
3.
Install bridging clips as required.
OR
To connect to the PGD(2)-U( ) ADP:
4.
Make sure the jumper in the PGD(2)-U( ) ADP for the channel is
set correctly. (Refer to
Settings on page
D
B
/P
OOR
OX
AGE
Figure 10-4 PGD(2)-U( ) ADP Jumper
10-4).
Installing SV8100/SV8300 Optional Equipment