Installation - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue No. 1.5
6 - 54
Connector for CD-4LCA and CD-8LCA Blades
One extension status LED
Two status LEDs
Ring Generator
Caller ID Sending Ability
Message Wait Lamp Ability
Constant current type battery feeding (25mA / -28Vdc)
Feeding Polarity Reverse Ability
Each CN2 (PZ-4LCA/PZ-8LCE) and CN3 (PZ-8LCE only) connector
provides connection to four analog station ports and is not polarity
sensitive. The PZ-8LCE consumes eight ports ranging between ports
001~256 (remember that the CD-8LCA consumes eight ports).
Refer to the following table for maximum upgrade capacity of the
PZ-4LCA
PZ-8LCE SLI daughter boards:
/
Table 2-4 SV8100 Maximum System Capacities – Blades on
page 2-7
4.4.2

Installation

This daughter board can be installed on the CD-4LCA or CD-8LCA
blade.
To install the PZ-4LCA
1.
Included with thePZ-4LCA
Install the plastic spacers on either the CD-4LCA or CD-8LCA.
Make sure to attach the spacers so that they extend out on the
side of the daughter board which has the CN1 connector.
6-18 Installing the PZ-4LCA Daughter Board on page 6-52
Figure 6-19 Installing the PZ-8LCE Daughter Board on
page 6-53
PZ-8LCE daughter boars..
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The CD-4LCA/CD-8LCA blades and the
PZ-4LCA/PZ-8LCE daughter boards are
categorized as TNV2. With this designation,
off-premise wiring is not acceptable. Any
cabling to these blades or daughter boards
must be within the building – no outside
cabling is permitted.
Branch connection is not acceptable.
/
:
PZ-8LCE
/
PZ-8LCE are four plastic spacers.
show the location of the connectors on the PZ-4LCA
Installing the SV8100/SV8300 Blades
UNIVERGE SV8100/SV8300
Figure
and
/

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300