Power Requirements; Power Supply Specifications - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue No. 1.5
6.2
2 - 18

Power Requirements

A dedicated
50 Hz circuit located within seven feet of the chassis is
240VAC
required. A separate dedicated outlet for each chassis should be installed.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N side).
6.2.1

Power Supply Specifications

AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 240VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=276VA, Expansion
Chassis=276VA, total 1104VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC - 240VAC)
Frequency: 45Hz - 66Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage: D
With input voltage of 240VAC and with full load conditions:
Output Power: Base chassis=
544W
AC Input I: Base chassis=
VA @ 240V: Base chassis=
1104VA
KWh @ AC Input I x 240V/1000: Base chassis=0.276 KWh,
Expansion chassis=0.276 KWh, total 1.104 KWh
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
Dedicated 240VAC
50/60 Hz circuit located within seven feet of the chassis
Dedicated 15A circuit
Single Phase
UNIVERGE SV8100/SV8300
term
/OPX/DID: -48V
SLT: 25mA / -28V
, Expansion chassis=
136W
, Expansion chassis=
1.15A
, Expansion chassis=
276VA
SV8100 System Specifications
, total
136W
, total
1.15A
4.6A
, total
276VA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents