Uninstalling a Blade Slot Through Software
The installer can turn off (busy out) and delete (remove from software) blade
slots in the Controlling and Expansion Chassis in programming for port
renumbering or to replace it with a different blade. Deleting a blade may affect
blade slot programming capability. Refer to Program 90-05 in the UNIVERGE
SV8100 Programming Manual for detailed programming information.
Blade Capacities
The universal architecture of the UNIVERGE SV8100/SV8300 provides
flexibility when installing blades. With the exception of the CD-CP00-AU and
CC-CP00 blades, any blade can be installed in any slot.
Maximum System Capacities – Blades on page 2-7
and the maximum capacities with various chassis configurations.
Powering Up the SV8100
2.6.1
Performing a Cold Start
This section describes the process for starting the system for the first
time or starting a system that has been turned off.
System software loaded from flash memory and the
customer data is erased from RAM memory.
To avoid extension and trunk renumbering, if certain
blades are recognized first, remove them from their
respective slots until the system has been reset. Then,
slot the blade cards in the correct order to retain the
proper system numbering. (Use Program 10-03 prior to
performing a cold start to record the current slot
definitions..
To perform a cold start:
1.
Turn the system power off.
2.
Once the system has powered down, push in and hold the Load
button.
3.
Turn the power switch back on to power the system back up.
With a multi-chassis system, turn on the Expansion Chassis
power supply, then the Controlling Chassis power supply.
4.
Continue holding the Load button for approximately three
seconds or until LED 2 starts flashing red.
IMPORTANT CONSIDERATIONS
Issue No. 1.5
Table 2-4 SV8100
provides a list of the blades
6 - 7