3.1.2

Installation

Each SV8100 system must have the CD-CP00-AU installed in Slot
1 of the Controlling Chassis.
1.
Install the battery on the CD-CP00-AU. The polarity "+" symbol
must be on top as illustrated in
Installation.
2.
Refer to
Installed on page 6-14
and/or PZ-32IPLA/PZ-64IPLA/PZ-128IPLA daughter board, if
required.
IMPORTANT INSTALLATION NOTES
The chassis power must be off when installing or
removing the CD-CP00-AU.
After removing a previously installed
CD-CP00-AU, handle the blade, carefully, from
the edges. If certain solder points/resistors are
touched on the back of the blade, some RAM/
temporary memory may be lost (e.g., time, date,
user-defined settings, etc.)

Figure 6-5 CD-CP00-AU Battery Installation

Figure 6-4 CD-CP00-AU Blade with Daughter Boards
to Install the PZ-VM21, PZ-ME50-AU
Issue No. 1.5
Figure 6-5 CD-CP00-AU Battery
6 - 17