Two Power Failure Transfer Circuits
Connection for PZ-4COTG Daughter Board
The CD-4COTC blade consumes four trunk ports ranging between
ports 001~200. The CN2 connector provides connection to four
analog trunk ports..
Refer to the following tables for maximum upgrade capacities of the
CD-4COTC blade:
Table 2-4 SV8100 Maximum System Capacities – Blades on
page 2-7
5.1.2

Installation

Install the CD-4COTC blade into an available slot in the chassis.
(Refer to
Figure 6-21 CD-4COTC Blade on page 6-60
the blade.)
If the PZ-4COTG is to be used, install this prior to inserting the CD-4COTC blade
into the chassis.
When using the CD-4COTC blade for ground
start trunks, the PBX ground must be
connected as described in
the SV8100
Chassis,
Chassis Grounding on page 4-34
do not function correctly.
When connecting the RJ-61 cables to the
CD-4COTC blades, note the position of the
Power Failure connector (CN3). Do not
confuse this connector as the trunk connector
(CN2).
Do not wire an RJ-11 directly to the
CD-4COTC interface. Use the appropriate
RJ-61 wiring when connecting to the
CD-4COTC.
Issue No. 1.5
Chapter 4 Installing
section 3.5.5 Install 19"
or the trunks
for a layout of
6 - 61