Number
33 0042
33 0043
33 0044
33 0045
33 0046
33 0047
33 0048
33 0049
33 0050
33 0051
33 0052
33 0053
33 0054
33 0055
33 0056
33 0057
33 0058
33 0059
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
Name
F cmnd mgf
This multiples the commanded F command value
type/rot
(per rotation) using no decimal points.
Subpro stor
If D1 to D4 is designated when calling the
D0: dev
subprogram, the subprogram to be called will be
searched from the storage destination (device and
Subpro stor
directory) designated with this parameter.
D0: dir
Subpro stor
(Example)
D1: dev
The following will be searched:
Subpro stor
M98 P (program No.), D0
D1: dir
Device : "330043 Subpro stor D0:dev" device
Directory : "330044 Subpro stor D0:dir" directory
Subpro stor
D2: dev
(Note 1) If the called subprogram is not found in the
Subpro stor
designated storage destination, a program
D2: dir
error will occur.
Subpro stor
D3: dev
(Note 2) If D0 to D4 is not designated when calling
Subpro stor
the subprogram, the subprogram will be
D3: dir
searched for according to the setting of
"330030 Subpro search 1: dev to 4: dir".
Subpro stor
D4: dev
Subpro stor
D4: dir
Spline
If the angle created by two continuing blocks
cancel angle
exceeds this setting value, the high-accuracy spline
function will be temporarily canceled. Set the angle
for creating an edge.
Minute line
This is valid during the high-accuracy spline control.
length
Curve interpolation will be carried out on linear
blocks of which the length of one block is less than
this setting value.
Tolrnc
This corrects the curve shape so that the spline
(inflctn)
curve's helical difference is within this setting value
for blocks containing an inflection point.
Tolrnc
This corrects the curve shape so that the spline
(smooth)
curve's helical difference is within this setting value
for blocks not containing an inflection point.
Tolrnc
This thins out blocks of which the block length does
(thin out)
not satisfy this setting value.
Tolrnc
This corrects the path so that the path correction
(fairing)
amount by faring with less than this setting value.
Tolrnc
This corrects the curve shape so that the error
(ACCS)
separated from the original path caused by ACCS
control is within the setting value.
search engine
3. Setup Screens
Details
Device
Drive name
Memory
MO1
Data server
DS
IC card
IC
Floppy disk
FD1
Hard disk
HD
I – 159
Setting range (units)
0: 1-fold
1: 1/10-fold
2: 1/100-fold
Drive name
Directory 20 characters
Drive name
Directory 20 characters
Drive name
Directory 20 characters
Drive name
Directory 20 characters
Drive name
Directory 20 characters
0 to 90 ( ° )
(Standard value: 60)
0 to 10 (mm)
0: 1
(mm)
(Standard value: 0)
0 to 100 (mm)
(Standard value: 0.01)
0 to 100 (mm)
(Standard value: 0.01)
0 to 10 (mm)
(Standard value: 0.01)
0 to 10 (mm)
(Standard value: 0.1)
0 to 10 (mm)
(Standard value: 0.25)

Advertisement