2.1.2 Executing manual value commands

Each value for S, M, T and B can be set and executed using the menu
Four values each for the S command and M command, two values for the T command and one value for
the B command can be set.
The manual value command can be set and executed by inputting an address such as S, M or T.
Refer to "1.5.1 Setting a manual value command" for the setting method.

2.1.3 Presetting the counter (Counter set, origin set, origin cancel)

Counter set, origin set and origin cancel can be executed on this screen.
The counter set, origin set and origin cancel can be executed only when the counter display is the current
position.
(1) Differences between counter set, origin set and origin cancel
Function
Changes in
the counter
value
Offset
The counter set mode can also be entered by inputting the axis name address.
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
2. Monitor (Operation) Screens
Counter set
A random value is
set in the current
position counter.
The setting data
appears in the
current position
counter only.
search engine
Origin set
The coordinate system is
shifted so the current
position becomes the zero
point of the workpiece
coordinate system.
This is equivalent to "G92
X0". (When X is the target
axis.)
The current position counter
and workpiece coordinate
counters become "0".
The G92 shift amount is
updated.
I – 31
.
Manual value
Origin cancel
The coordinate system is shifted
so the zero point of the
workpiece coordinate system
matches the zero point of the
basic machine coordinate
system.
This is equivalent to "G92 G53
X0". (When X is the target axis.)
The current position counter
matches the machine coordinate
counter.
The G52 shift amount of the G92
shift amount and G54 to G59
shift amount becomes "0".