Error No.
PR0111
PR0112
PR0120
PR0121
PR0122
PR0124
PR0125
PR0140
PR0141
PR0142
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 3. Alarm Messages
Message
A plane selection command (G17,
Coord rotation plane
G18, G19) has been issued in a
selection
coordinate rotation command
(G68).
A plane selection command (G17,
Plane selected
G18, G19) has been issued when
during R compen
the tool radius compensation
command (G41, G42) is issued.
Synchronous feed was
No synchronous
commanded even though there
feed spec.
are no synchronous feed
specifications.
The F0 command (F1-digit rapid
In F0 arc modal
traverse command) has issued
mode
when the circular interpolation
command (G02, G03) was issued
during the F1-digit feed command.
No auto corner
An automatic corner override
command (G62) was issued
override spec.
despite the fact that such a
command does not exist in the
specifications.
The inverse time feed option is
No G93 spec.
not provided.
A G command that cannot be
G93 mode error
commanded in the G93 mode
was issued. Or, the G93 was
commanded in a mode incapable
of inverse time feed.
The tool position compensation
No t-pos offset
option is not provided.
Tool position compensation was
T-pos during
attempted during figure rotation or
pat/cood rot
program coordinate rotation.
T-pos offset G3 error An arc command with which
position compensation is not
possible was issued.
search engine
Details
• Upon completion of the G68
command, the plane selection
command must be issued
following the G69 command
(coordinate rotation cancel).
(For the program based on the
M2/M0 format, the coordinate
rotation command is G68.1 and
the coordinate rotation cancel
command is G69.1.)
• Issue the plane selection
command after the tool radius
compensation command has
been completed (issue the G40
cancel command.)
• Check the specifications.
• Change the synchronous feed
command (G95) to a feed per
minute command (G94).
(Also change the F command
value.)
• Rapid traverse cannot be
commanded and so any F1-digit
command except F0 should be
designated for the circular
interpolation command.
• Issue the G0 or G1 command
unless the block which caused
the alarm is the circular
command block.
• Check the specifications. Delete
the G62 command from the
program.
• Check the specifications.
• Reconsider the program.
• Check the specifications.
• Reconsider the program.
• Reconsider the program.
IV – 38