6.18.8 Operation sequence
An operation example is given where automatic operation of XYZ axes is executed in the memory
operation mode and the Z axis is used as a handle interrupt axis.
Perform automatic operation.
Turn ON the HANDLE INTERRUPT
switch on the machine operation panel.
Select interrupt axis by setting the
HANDLE AXIS SELECT switch on the
machine operation panel.
Select the travel distance per handle
graduation by setting the HANDLE/
INCREMENTAL MAGNIFICATION
switch.
Turn the manual handle in the + or -
direction and change the Z axis cut depth
amount.
When M02 or M30 is executed, automatic
operation will stop.
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
search engine
HANDLE INTERRUPT
ON
OFF
HANDLE/
INCREMENTAL
MAGNIFICATION
1
1000
10
5000
1000
100
10000
100
100
10
50000
10
1000
1
100000
1
Tool path
(handle interrupt display)
Handle interrupt
II – 44
HANDLE FEED
AXIS SELECT
Z
Y
X
4
Z
X
Program path
(current position
display)