Appendix 4. Warning Messages
4.1 Warnings common to all systems (SYW
No.
SYW0001
SYW0002
SYW0003
SYW0004
SYW0005
SYW0006
SYW0007
SYW0008
SYW0009
SYW0040
SYW0050
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
Message
External switch
An external emergency stop
emergency stop
input signal was received. (24V
is not being applied to the CN23
connector.)
RIO1
An emergency stop input signal
communication
was received from a remote I/O
error
unit (RIO1). Or, the
communication cable with the
remote I/O unit (RIO1) is not
connected properly.
RIO2
An emergency stop input signal
communication
was received from a remote I/O
error
unit (RIO2). Or, the
communication cable with the
remote I/O unit (RIO2) is not
connected properly.
RIO3
An emergency stop input signal
communication
was received from a remote I/O
error
unit (RIO3). Or, the
communication cable with the
remote I/O unit (RIO3) is not
connected properly.
PLC emergency
The user PLC (ladder
stop
sequence) is not running.
This error also occurs when an
error occurs in the data
communication with the remote
I/O.
PLC signal
An emergency stop signal was
input from the PLC.
EMG stop: SV
This appears when the power is
commu stop
OFF.
Ext board EMG
An emergency stop occurred
stop: SV end off
because the servo terminator or
battery is not connected
properly.
RIO4
The emergency stop input
communication
signal was input from the
error
remote IO unit (R104). The
communication cable with the
remote IO unit (R104) is
disconnected.
The others EMG
An emergency stop occurred for
some other reason.
Low battery
The voltage of the battery
voltage
provided for saving data in the
NC has dropped.
search engine
)
Details
• Examine the causes of the
emergency stop, and remove
them.
• Examine the causes of the remote
I/O unit emergency stop, and
remove them.
• Check the cable connection.
• Examine the causes of the remote
I/O unit emergency stop, and
remove them.
• Check the cable connection.
• Examine the causes of the remote
I/O unit emergency stop, and
remove them.
• Check the cable connection.
• Turn ON the PLC ladder RUN
switch on the CPU Card. (Second
switch from the top of the
QX
• Check whether there is an
abnormality in the connection
between the NC main unit and
remote IO unit.
• Cancel the signal with a machine
switch such as READY.
• This is not a particular problem.
• Check the connection status of
the servo communication cable
and connectors.
• Check and remove the cause of
the remote IO unit emergency
stop.
• Check the cable connection.
• Contact the Service Center.
• Charge the battery.
• Replace the battery.
• Check the machining program
after replacing or charging the
battery.