Mitsubishi Electric MELDAS 600M Series Instruction Manual page 364

Table of Contents

Advertisement

6.16 F1 digit feed
(1) Turning ON the "F1 DIGIT FEED" switch enables the feedrate to be increased/decreased by
turning the handle when the feedrate in the program is an F1 digit.
(2) The increase/decrease amount per handle gradient is expressed with the following equation.
(Example) For a 10mm/min. increase/decrease amount per handle gradient:
(3) The conditions for validation are as follows:
(a) The operation must be automatic (program run, MDI).
(b) The operation must be in automatic start.
(c) The operation must be in cutting feed, and F1 digit feedrate command must be issued.
(d) The F1 digit feed parameter must be ON.
(e) The F1 digit feed switch must be ON.
(f) The operation must not be in machine lock.
(g) The operation must not be in dry run.
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
F max
F =
K
If F max = 3600mm/min :
3600
F = 10 =
K
Thus, K = 360
search engine
K
:
Operation constant (parameter setting value)
F max
:
F1 - F4 max. speed (FM1 parameter setting value)
:
F5 - F8 max. speed (FM2 parameter setting value)
II – 31

Advertisement