6.18.5 Path resulting after handle interruption
(1) For incremental value (G91) mode
(2) For absolute value (G90) mode
(Note) Each of the POSITION and MACHINE display includes the distance of handle interruption.
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
The locus deviates from the program path by the distance of interruption. (See the figure below.)
If program absolute value update by the distance of handle interruption is disabled, the locus
deviates from the program path by the distance of interruption.
If this update is enabled, the locus returns to the program path during processing of the
following command:
For single block running — Return command is issued in the block next to the one for which
the interruption has been completed.
For continuous running — Return command is issued in the third block, if the block for which
the interruption has been completed is the first block.
For automatic handle interruption, select whether absolute data is updated or not, as follows:
1)
Using machine parameters, set whether the manual absolute changeover switch or
parameters are used.
2)
If the parameters are used, set whether or not absolute data is updated for each axis, by
using machine parameters other than those in item .
3)
If the manual absolute changeover switch is used, use the machine operation panel
switch for selection.
search engine
Path after interruption
(Incremental value mode)
II – 39