Fujitsu ETERNUS DX80 S2 Cli User's Manual page 194

Disk storage systems
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 3 Configuration Settings and Display
3.5 Host Interface Management
Mapping method
The following is an example when Host Affinity Mode is enabled:
CLI> set fc-parameters -port 000 -host-affinity enable
CLI> create raid-group -name r1 -level 1 -disks 006,007
CLI> create volume -name v -count 3 -rg-name r1 -type open -size 256mb
CLI> create affinity-group -name a1 -volume-name v0,v1,v2 -lun 0-2
CLI> create host-wwn-name -name h1 -wwn a00000e0d0100000
CLI> set host-affinity -host-name h1 -ag-name a1 -port 000
Procedure
1
Enable Host Affinity Mode of host interface port 000. (FC)
2
Create a RAID group named "r1".
3
Create volumes named "v0", "v1" and "v2" in the RAID group named "r1".
4
Create an affinity group named "a1", the mapping relation of volume named v0/v1/v2 and
LUN 0/1/2.
5
Register a host WWN named "h1" (FC).
6
Use mapping (host affinity mode) to set the relationship between host interface port 000,
the affinity group named "a1", and the host identifier named "h1".
The following is an example when Host Affinity Mode is disabled:
CLI> set fc-parameters -port 000,001 -host-affinity disable
CLI> create raid-group -name r1 -level 1 -disks 006,007
CLI> create volume -name v -count 3 -rg-name r1 -type open -size 256mb
CLI> set mapping -volume-name v0,v1,v2 -lun 0-2 -port 000,001
Procedure
1
Disable the Host Affinity Mode (FC).
2
Create a RAID group named "r1".
3
Create volumes named "v0", "v1" and "v2" in the RAID group named "r1".
4
Use mapping to set the relationship between host interface ports 000 and 001, volumes v0,
v1, and v2, and LUNs 0, 1, and 2.
194
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
End of procedure
End of procedure
P2X0-1030-09ENZ0