Chapter 5 Information Settings and Display
5.3 Maintenance > export log
-starting-time
-ending-time
-last-24h
-iom-log
The following conversion specifications, which begin with a percent character, are replaced by
their corresponding values during file creation.
If other conversion strings are specified, this command terminates abnormally with an error
message.
%s Serial number of the system
Example:
/tmp/%s-log.bin -> /tmp/123456789012-log.bin
%d Current date
Example:
/tmp/%d-log.bin -> /tmp/20080819-log.bin
%t Current time
Example:
/tmp/%t-log.bin -> /tmp/144855-log.bin
%% Percent character
Example:
/tmp/log%%.bin -> /tmp/log%.bin
Optional. Log entries can be restricted to a specific time range. This parameter specifies the
starting time. The format is "YYYYMMDD-hhmmss": "YYYY" is the number of the year (a four-
digit number), "MM" is the number of the month (01-12), "DD" is the number of the day (01-
31), "hh" is the hour in 24-hour time (00-23), "mm" is the minute (00-59), and "ss" is the
second (00-59). If omitted, the start time is the earliest entry (except when the "-last-24h"
parameter is specified).
Note that both the starting time and ending time must be specified. If these parameters are
specified, the "-last-24h" parameter cannot be specified.
Optional. Log entries can be restricted to a specific time range. This parameter specifies the
ending time. The format is "YYYYMMDD-hhmmss": "YYYY" is the number of the year (a four-
digit number), "MM" is the number of the month (01-12), "DD" is the number of the day (01-
31), "hh" is the hour in 24-hour time (00-23), "mm" is the minute (00-59), and "ss" is the
second (00-59). If omitted, the start time is the latest entry (except when the "-last-24h"
parameter is specified).
Note that both the starting time and ending time must be specified. If these parameters are
specified, the "-last-24h" parameter cannot be specified.
Optional. Log entries can be restricted to the last 24 hours. If this parameter is specified, the
starting time and ending time parameters may not be specified. If this parameter is omitted,
this function may not be used.
enable
Log entries are restricted to the last 24 hours.
disable
Log entries are not restricted to the last 24 hours.
Optional. This parameter specifies whether the I/O module logs are included. If omitted, I/O
module logs are included.
enable
The I/O module log is included.
disable
The I/O module log is not included.