Chapter 4 Function/System Settings and Display
4.2 Advanced Copy Management
path-type {direct | switched}
line-speed {1-65535}
X
port-link cm
Defines the type of path connection between the linked storage systems. If the storage
systems are directly connected (P2P), use "direct". If the storage systems are connected
through a switch, use "switched". Direct connection example:
path-type direct
Switched connection example:
path-type switched
Defines an effective line speed for the path between the linked storage systems. This is the
WAN bandwidth that is actually available and used for the REC. The possible range is from 1
to 65535 and the units are megabits per second (= Mbit/s). This definition is only specified
for switched type paths. The following example specifies 100 Mbit/s as the effective line
speed:
line-speed 100
Y
Z
W
V
U
-ca
-port
,cm
-ca
-port
Respectively defines the target host interface ports in the local and remote storage systems
in the same order as used in the "storage-link" field. In the following example, for the
"storage-link 5,6" used in the above storage system definition example, cm0-ca0-port1
belongs to storage system #5 and cm1-ca2-port3 belongs to storage system #6. In the
"cmX-portY-portZ,cmW-portV-portU" format, X and W indicate the controller module
number, Y and V indicate the host adapter on the specified controller module (0 is specified
for the ETERNUS DX90 S2), and Z and U indicate the host interface port number of the
specified host adapter.
port-link cm0-ca0-port1,cm1-ca2-port3
Note that space characters may not be inserted before and after the commas (,). The
following example has a space character after the comma (a syntax error):
port-link cm0-ca0-port1, cm1-ca2-port3