Chapter 4 Function/System Settings and Display
4.4 Miscellaneous > set power-synchronization

set power-synchronization

This command configures the way in which the shutdown function interacts with the external sensor.
Syntax
set power-synchronization [-cm { 0 | 1 | all | none }] [-svc { 0 | 1 | all | none }]
[-auto-power {enable | disable}] [-resume-power {enable | disable}] [-shutdown-time
[-preset { power-sync | pman | manual}] [-power-fail-signal { positive | negative }]
[-low-battery-signal { positive | negative }] [-ups-shutdown-signal { positive | negative }]
[-ups-shutdown { enable | disable }]
Parameter
-cm
-svc
-auto-power
-resume-power
Optional. This parameter specifies which controller module connects to the external sensor.
The connection method conforms to the RS-232C standard. If omitted, the existing setting is
not changed. This can only be set for ETERNUS DX80 S2/DX90 S2 and ETERNUS DX410 S2/
DX440 S2.
0
Controller module #0
1
Controller module #1
all
Both Service Controller #0 and Service Controller #1
none
No connection. If selected, only "-auto-power" and "-resume-power" from the
parameters that follow can be selected.
Optional. This parameter specifies which service controller connects to the external sensor. The
connection method conforms to the RS-232C standard. If omitted, the existing setting is not
changed. This parameter can only be set for the ETERNUS DX8700 S2.
0
Service Controller #0
1
Service Controller #1
all
Both Service Controller #0 and Service Controller #1
none
No connection.
Optional. If "enable" is specified, the system power is turned on when an AC power supply is
detected. The default value is set to disable.
enable
Enabled.
disable
Disabled.
Optional. If "enable" is specified, the system power is turned on when an AC power supply is
detected after the ETERNUS DX Disk storage system is shutdown due to a power outage. The
default value is set to disable.
enable
Enabled.
disable
Disabled.
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
571
shutdown_time
]
P2X0-1030-09ENZ0