Code Restriction for outgoing calls is based on the first eight digits dialed.
Code Restriction denies outside calls based on number dialed over a trunk
group and accommodates equal access to Other Common Carriers (OCCs)
and CO Feature Codes. This eliminates unauthorized calls and configures
system calling functions to provide cost control.
Terminal Type:
All Multiline Terminals
Required Components:
None
When a station user attempts an outside call to a station that is
code restricted, the following occurs:
1.
The user goes off-hook, waits for internal dial tone, and dials a Trunk
Access Code or goes off-hook on an outside line.
2.
The user receives an outside dial tone, and dials a restricted
telephone number.
3.
A reorder tone is generated, and ERROR is displayed on terminals
with an LCD.
Data Assignment:
¥
Use Memory Block 1-1-61 (8-Digit Matching Table to Class Assignment)
to assign each Class (01~14) to individual tables (00~15) as NON, Allow
(default: YS) or Deny (NO) Class Assignment.
Use Memory Block 4-07 [Code Restriction Class Assignment (Day
¥
Mode)] and 4-08 [Code Restriction Class Assignment (Night Mode)] to
assign each station to a Code Restriction Class.
C-19