Electra Elite
SERVICE
CONDITIONS
Features and Specifications Manual
To answer by Two Levels:
1.
Receive an incoming CO/PBX call.
2.
The Automatic Answer with Delay Message answers the call and
sends a greeting.
3.
The outside party hears ringback tone or MOH (System
Programmed).
4.
After the time expires, a second message is played.
5.
The outside party hears ringback tone or MOH until the call is
answered.
Data Assignment:
A maximum of two VRS(4)-U10 ETUs, four channels per ETU, can
¥
be used for Automated Attendant.
Each channel has 240 recording seconds that can be subdivided into
¥
2, 4, 8, or 16 equal recording times.
A maximum of eight Automated Attendants can be assigned.
¥
Use Memory Block 1-4-11 (Automated Attendant Message Day/Night
¥
Mode Selection) to assign the Day/Night/Weekend mode greeting
messages to each Automated Attendant position.
Use Memory Block 1-4-13 (Automated Attendant Answer Delay Time
¥
Assignment) to set the answering time (default: 4 seconds) between
when the incoming CO/PBX call rings and when it is answered. This
time affects the Day/Night/Weekend mode settings per Automated
Attendant.
Use Memory Block 1-4-16 (Automated Attendant Message Repeat
¥
Selection) to assign the number of times a greeting message is
repeated (default: 1).
Use Memory Block 1-8-07 [Class of Service (Attendant) Feature
¥
Selection 1] Page 1 LK8 to Allow (default: LED On) or Deny (LED
Off) Attendant Positions to set/reset the Automated Attendant per
trunk.
Use Memory Block 1-8-08 [Class of Service (Station) Feature
¥
Selection 2] Page 2 LK6 to Allow (default: LED On) or Deny (LED
Off) the station to record, verify, or erase an Automated Attendant
message.
Issue 6