S - 48
Use Memory Block 1-5-25 (SMDR Valid Call Time Assignment) to
¥
specify the SMDR Valid Call Time (default: 040s) before SMDR
outputs a record. Incoming transfer or conference calls and outgoing
calls are not output through SMDR until the SMDR Valid Call Time
has elapsed.
Use Memory Block 1-5-26 (SMDR Incoming/Outgoing Print
¥
Selection) to assign SMDR to output incoming calls (INC), outgoing
calls (default: OUT), or ALL Calls.
Use Memory Block 4-56 (SMDR Telephone Print Selection) to
¥
specify whether (default YES) or not (NO) a call record is printed for
the specified station. System Software S5000 or higher and MIFM
Software Version 3.00 or higher are required.
¥
Use Memory Block 7-1 (Card Interface Slot Assignment) to specify
the required MIFM-U10 ETU.
¥
Use Memory Block 7-3-01 [MIF (LCR) Assignment] to specify LCR.
¥
Use Memory Block 7-3-02 [MIF (SMDR) Assignment] to specify
SMDR.
Restrictions:
Call records are not provided for internal calls.
¥
Caller ID name is not printed on SMDR.
¥
¥
When the system automatically switches the clock for daylight saving
time and a station is on a call, the duration of that call is invalid.
System Software S6000 or higher with Automatic Daylight
Saving Time Selection set to allow affects this.
General:
¥
When the printer or other I/O device fails to operate, approximately
100 call records are saved in the MIFM-U10 ETU buffer. When the
buffer is full, the first call record is lost and the last call record is
stored.
¥
Call record data provides the Start Time, Trunk Number, Trunk
Group, Type of Call, Station Number, Duration, Number Dialed, LCR,
Calling Station Number, and Transferred Station Number.
¥
The maximum digits allowed for output of a telephone number is 24.
¥
When Printer is assigned, and a printer is not connected to the
system, a PRINTER TROUBLE LCD indication and an audible alert
tone are provided at the first two Multiline Terminals connected to the
system (Stations 100 and 101). When an MIFM-U10 ETU is not
installed or disabled, no alarm indication is given.
Station Message Detail Recording (SMDR)