3.2 Inspection activities
3.2.1 Inspection of the controller
Inspection
The procedure below describes how to inspect the IRC5 controller.
1
2
3
Product manual - IRC5
3HAC047136-001 Revision: M
WARNING
Please observe the following before commencing any repair work on the IRC5
controller, or units connected to the controller:
•
Switch off all electric power supplies with the power switch!
•
Before handling, make sure you are grounded through a special ESD wrist
bracelet or similar. Many components inside the module are sensitive to
ESD (ElectroStatic Discharge) and can be destroyed if exposed to discharge.
See the Safety chapter,
Action
Inspect all sealing joints and cable
glands to make sure they are airtight
in order to prevent dust and dirt from
penetrating into the controller cabinet.
Inspect connectors and cabling to
make sure they are securely fastened
and cabling not damaged.
Inspect the heat exchanger and the fan
on the controller to make sure it is
clean.
© Copyright 2004-2018 ABB. All rights reserved.
3.2.1 Inspection of the controller
The unit is sensitive to ESD on page 34
Note/Illustration
xx0500001952
Parts:
•
A: fan
•
B: heat exchanger
•
C: top cover
•
D: attachment screw (4 pcs)
3 Maintenance
Continues on next page
185