3
4
5
6
Connection through a connector
The following procedures detail how to connect the mains power to the controller
through a connector.
Product manual - IRC5
3HAC047136-001 Revision: M
Action
Strip the insulation on the power supply
cable long enough to reach the rotary
switch.
Connect the ground cable at the ground-
ing point.
Route the phase wires through the pipe
up to the rotary switch.
Connect the wires as shown in the illus-
tration.
CAUTION
Always inspect the connector for dirt or damage before connecting it to the
controller. Clean or replace any damaged parts.
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
2.5.4 Connecting power supply to the controller
Note/illustration
See illustration in step 2.
Tightening torque, 4.5 Nm.
See illustration in step 2.
For three phase:
xx0500001882
For single phase:
xx1100000019
For single phase, pin 5 is plugged.