Equipment
Standard toolkit
Other tools and procedures
may be required. See refer-
ences to these procedures in
the step-by-step instructions
below.
Circuit diagram
Removal
The procedure below details how to remove the customer I/O power supply.
1
2
3
4
5
6
Product manual - IRC5
3HAC047136-001 Revision: M
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
Make sure that the main power has been switched
off on page
26.
Remove the Flange disconnect unit (option).
Loosen the terminal screws for each connected
wire. Remove wires from the terminals.
Loosen the DIN-lock fixing screw.
Pull the DIN-lock lever downwards to release the
power supply unit.
Remove the power supply unit.
© Copyright 2004-2018 ABB. All rights reserved.
4.26.2 Replacement of customer I/O power supply
Article number
See
Circuit diagrams on
page
325.
4 Repair
Continued
Note
The contents are defined in
section Standard toolkit.
These procedures include
references to the tools re-
quired.
Note/Illustration
Detailed in section
Replacement
of Flange disconnect on page 213
xx0700000124
A: DIN-lock fixing screw
B: DIN-lock lever
Continues on next page