Refitting
The procedure below details how to refit the contactor board.
1
2
3
4
5
6
7
Product manual - IRC5
3HAC047136-001 Revision: M
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety informa-
tion in section
Make sure that the main
power has been switched off on page
WARNING
The unit is sensitive to ESD. Before handling
the unit please read the safety information
in the section
The unit is sensitive to ESD
on page 34
If SafeMove is used, mount the plugs in the
limit switch override contact (X23) pin 1 and
4.
Refit the contactor interface board.
Refit the attachment screws.
Reconnect all connectors.
Perform the function tests in section
tion tests on page 196
to verify that the safety
features work properly.
© Copyright 2004-2018 ABB. All rights reserved.
4.19 Replacement of Contactor Interface Board
Note/Illustration
26.
Note
The limit switch override contact must be
plugged and not used when using Safe-
Move.