3.1 Maintenance schedule, controller IRC5

General
The controller must be maintained at regular intervals to ensure its function. The
maintenance activities and their respective intervals are specified below:
Certain activities to be performed as specified in the Maintenance Schedule are
not all detailed in this chapter, but in the Repair chapter.
Please refer to the Repair chapter of the equipment in question.
Intervals
Equipment
Complete controller modules
Moist dust filter
Moist dust filter
Heat exchanger fan
Heat exchanger fan
FlexPendant
Earth fault breaker F4 (tested
if used)
Emergency stop (operating
panel)
Emergency stop (FlexPend-
ant)
Mode switch
Enable device
Motor contactors K42, K43
Brake contactor K44
Auto stop (tested if used)
General stop (tested if used)
Superior stop (tested if used)
Product manual - IRC5
3HAC047136-001 Revision: M
Maintenance
activity
Inspection
Cleaning
Replacement
Inspection
Cleaning
Cleaning
Function test
Function test
Function test
Function test
Function test
Function test
Function test
Function test
Function test
Function test
© Copyright 2004-2018 ABB. All rights reserved.
3.1 Maintenance schedule, controller IRC5
Interval
Note
12 months *
Inspection of the controller on
page
185.
Cleaning moist dust filter on
page 191
24 months *
Replacement of moist dust
filter on page 187
6 months *
Inspection of the controller on
page
185.
12 months *
Cleaning of the controller
cabinet on page
When needed
Cleaning the FlexPendant on
page
193.
6 months
Function test of earth fault
breaker F4 on page 196
12 months
Function test of emergency
stop on page 197
12 months
Function test of emergency
stop on page 197
12 months
Function test of mode switch
on page 198
12 months
Function test of three-position
enabling device on page 199
12 months
Function test of motor contact-
ors K42 and K43 on page 200
12 months
Function test of brake contact-
or K44 on page 201
12 months
Function test of auto stop on
page 202
12 months
Function test of general stop
on page 203
12 months
Function test of superior stop
on page 204
Continues on next page