4 Repair
4.21 Replacement of sensors for the drive system fans
Continued
4
5
6
7
8
9
10
274
Action
Fit the sensor holder on the edge of the
fan channel bracket.
Refit the fan by placing the latches in the
back of the fan housing into the grooves
and press the fan down.
Slide the cable gland into the indentation
in the fan housing. Gently pull the cable
so there is no slack on the cable between
the sensor and the cable gland.
Reconnect the connectors to the fan.
Refit the cover and the attachment screws.
Refit the moist dust filter magazine. (Op-
tion)
Perform the function tests in section
Function tests on page 196
the safety features work properly.
© Copyright 2004-2018 ABB. All rights reserved.
Note/illustration
A
xx1500000857
A Sensor holder
B Sensor cable
B
C
xx1500000856
A Fan
B Latches
C Grooves
D Temp sensor cable
E Cable gland
to verify that
B
A
E
D
Product manual - IRC5