Replacement Of Customer I/O Power Supply - ABB IRC5 Product Manual

Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

4 Repair

4.26.2 Replacement of customer I/O power supply

4.26.2 Replacement of customer I/O power supply
Location
The customer I/O power supply, DSQC 609, is located as shown in the figure below.
xx1300000813
A
B
C
Required equipment
Equipment
Customer I/O power supply
Continues on next page
290
A
B
C
Customer I/O power supply
Power distribution unit
System power supply
CAUTION
If there are two or more Customer I/O power supply units mounted in a row and
too close to each other, there will be a heating problem and the units can be
damaged.
To avoid damaging the Customer I/O power supply units, the units must be
separated with 3 pcs of exterior support.
© Copyright 2004-2018 ABB. All rights reserved.
Article number
3HAC14178-1
Note
DSQC 609
Product manual - IRC5
3HAC047136-001 Revision: M