ABB IRC5 Product Manual page 214

Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

4 Repair
4.3 Replacement of Flange disconnect
Continued
Removal
The procedure below details how to remove the Flange disconnect unit.
1
2
3
Continues on next page
214
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
Make sure that the main power has been
switched off on page
26.
Remove the link by pushing the spring forward.
WARNING
Be careful when removing the link. The link is
spring-loaded and the spring can with high force
pull the link down when it is released.
Remove the two lower attachment screws.
© Copyright 2004-2018 ABB. All rights reserved.
Note/Illustration
xx0600003141
A: spring
B: link
xx0600003139
A: attachment screws
Product manual - IRC5
3HAC047136-001 Revision: M