2 Installation and commissioning
2.9.7 Installing the EPS board DSQC 646 for Electronic Position Switches
Continued
11
12
144
Action
Remove the power cable from the axis
computer and connect it to the split
cable.
Connect the split cable to the EPS board
and the axis computer.
Connect signal cables to the plug con-
tact, which is then connected to the I/O
connector of the EPS board.
Connect a power supply, 24 V to
pin 1 and 0 V to pin 2. Check with
a voltmeter that the voltage is 24
V between pin 1 and 2 on the
Phoenix connector.
Connect the output signals from
the EPS board (pin 3-12).
Connect the sync switch signals
to pin 13 and 14. If dual channel
wiring is not used, connect only
pin 14.