Table 5.7-2 Settings of LED indictors #3 to #14 (LED: Function ID: 201B01))
Setting items
LED#3 Color
Input signal1
Input signal2
Input signal3
Input signal4
Input signal5
Input signal6
Input signal7
Input signal8
LOGIC-SW
On Delay Timer
Off Delay Timer
INVERSE-SW
TIMER-SW
Off/Delay/Dwell/Latch/Blink
Logic Timer
Reset signal
LED#4 Color
Input signal1
Input signal2
Input signal3
Input signal4
Input signal5
Input signal6
Input signal7
Input signal8
LOGIC-SW
On Delay Timer
Off Delay Timer
INVERSE-SW
TIMER-SW
Off/Delay/Dwell/Latch/Blink
Logic Timer
Reset signal
LED#14 Color
Input signal1
Input signal2
Input signal3
Input signal4
Input signal5
Input signal6
Input signal7
Input signal8
LOGIC-SW
On Delay Timer
Off Delay Timer
INVERSE-SW
TIMER-SW
Off/Delay/Dwell/Latch/Blink
Logic Timer
Reset signal
Range
RED / GREEN / YELLOW
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
AND / OR / XOR
0.00 – 300.00
0.00 – 300.00
Normal / Inverse
0.00 – 300.00
(Preferred Data ID)
RED / GREEN / YELLOW
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
AND / OR / XOR
0.00 – 300.00
0.00 – 300.00
Normal / Inverse
0.00 – 300.00
(Preferred Data ID)
RED / GREEN / YELLOW
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
(Preferred Data ID)
AND / OR / XOR
0.00 – 300.00
0.00 – 300.00
Normal / Inverse
0.00 – 300.00
(Preferred Data ID)
Unit
Contents
s
-
LED#3 color selection
-
Set a Data ID at the first input on LED3
-
Set a Data ID at the second input on LED#3.
-
Set a Data ID at the third input on LED#3.
-
Set a Data ID at the forth input on LED#3.
-
Set a Data ID at the fifth input on LED#3.
-
Set a Data ID at the sixth input on LED#3.
-
Set a Data ID at the seventh input on LED#3.
-
Set a Data ID at the eighth input on LED#3.
-
Switch for logic-gate operation on LED#3
s
Set a value for an on-delay-timer on LED#3
s
Set a value for an off-delay-timer on LED#3
-
Inversion operation of LED#3 signal
-
Selection of a type in the delay timer on LED#3
s
Off delay timer value for "Delay" and "Dwell" circuit
-
Setting Data ID for "Latch" circuit
-
LED#4 color selection
-
Set a Data ID at the first input on LED#4
-
Set a Data ID at the second input on LED#4.
-
Set a Data ID at the third input on LED#4.
-
Set a Data ID at the forth input on LED#4.
-
Set a Data ID at the fifth input on LED#4.
-
Set a Data ID at the sixth input on LED#4.
-
Set a Data ID at the seventh input on LED#4.
-
Set a Data ID at the eighth input on LED#4.
-
Switch for logic-gate operation on LED#4
s
Set a value for an on-delay-timer on LED#4
s
Set a value for an off-delay-timer on LED#4
-
Inversion operation of LED#4 signal
-
Selection of a type in the delay timer on LED#4
s
Off delay timer value for "Delay" and "Dwell" circuit
-
Setting Data ID for "Latch" circuit
..........
-
LED#14 color selection
-
Set a Data ID at the first input on LED#14
-
Set a Data ID at the second input on LED#14.
-
Set a Data ID at the third input on LED#14.
-
Set a Data ID at the forth input on LED#14.
-
Set a Data ID at the fifth input on LED#14.
-
Set a Data ID at the sixth input on LED#14.
-
Set a Data ID at the seventh input on LED#14.
-
Set a Data ID at the eighth input on LED#14.
-
Switch for logic-gate operation on LED#14
s
Set a value for an on-delay-timer on LED#14
s
Set a value for an off-delay-timer on LED#14
-
Inversion operation of LED#14 signal
-
Selection of a type in the delay timer on LED#14
s
Off delay timer value for "Delay" and "Dwell" circuit
-
Setting Data ID for "Latch" circuit
- 559 -
6F2T0200 (0.15)
Default setting
value
RED
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
AND
0.00
0.00
Normal
Off
0.00
(No Assigned)
RED
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
AND
0.00
0.00
Normal
Off
0.00
(No Assigned)
RED
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
(No Assigned)
AND
0.00
0.00
Normal
Off
0.00
(No Assigned)
GRE200 (1,2)