Toshiba GR-200 Series Instruction Manual page 459

Multi functional protection ied
Hide thumbs Also See for GR-200 Series:

Advertisement

Signal name and number
(viii)
Note: The user should note the following descriptions shown in the column "M/O" for
each table:
"O" indicated that the signal is provided for optional use.
"M" indicates that the user should map/set/configure the signal; otherwise, the
"N/A" indicates that the user cannot change the state of the signal.
Table 4.1-1 PLC Connection points (Input points for Command 'On')
Signal Number
Signal Name
512001 800301EE32
DEV01_CL_COMMAND
512001 800302EE32
DEV02_CL_COMMAND
512001 800303EE32
DEV03_CL_COMMAND
....
....
512001 800348EE32
DEV72_CL_COMMAND
512001 800301EE33
DEV01_CL_INTERLOCK
512001 800302EE33
DEV02_CL_INTERLOCK
512001 800303EE33
DEV03_CL_INTERLOCK
....
....
512001 800348EE33
DEV72_CL_INTERLOCK
Table 4.1-2 PLC Connection points (Input points for Command 'Off')
Signal Number
Signal Name
512001 800301EE30
DEV01_OP_COMMAND
512001 800302EE30
DEV02_OP_COMMAND
512001 800303EE30
DEV03_OP_COMMAND
....
....
512001 800348EE30
DEV72_OP_COMMAND
512001 800301EE31
DEV01_OP_INTERLOCK
512001 800302EE31
DEV02_OP_INTERLOCK
512001 800303EE31
DEV03_OP_INTERLOCK
....
....
512001 800348EE31
DEV72_OP_INTERLOCK
Table 4.1-3 PLC Connection points (Interlock for Command 'On/Off')
Signal Number
Signal Name
570001 3103021DA2
DPOS01-Close
570001 3103031DA2
DPOS02-Close
570001 3103041DA2
DPOS03-Close
...
...
570001 3103481DA2
DPOS72-Close
570001 3103011DA0
DPOS01-Open
570001 3103021DA0
DPOS02-Open
570001 3103031DA0
DPOS03-Open
....
....
570001 3103481DA0
DPOS72-Open
user may experience an operational failure if the default settings are
used.
Description
DPOS01 PLC On-control checking with interlock(PLC#1)
DPOS02 PLC On-control checking with interlock(PLC#1)
DPOS03 PLC On-control checking with interlock(PLC#1)
....
DPOS72 PLC On-control checking with interlock(PLC#1)
DPOS01 PLC On-control without checking(PLC#2)
DPOS02 PLC On-control without checking(PLC#2)
DPOS03 PLC On-control without checking(PLC#2)
....
DPOS72 PLC On-control without checking(PLC#2)
Description
DPOS01 PLC Off-control checking with interlock(PLC#1)
DPOS02 PLC Off-control checking with interlock(PLC#1)
DPOS03 PLC Off-control checking with interlock(PLC#1)
....
DPOS72 PLC Off-control checking with interlock(PLC#1)
DPOS01 PLC Off-control without checking(PLC#2)
DPOS02 PLC Off-control without checking(PLC#2)
DPOS03 PLC Off-control without checking(PLC#2)
....
DPOS72 PLC Off-control without checking(PLC#2)
Description
DPOS01 interlock condition for On control.
DPOS02 interlock condition for On control.
DPOS03 interlock condition for On control.
...
DPOS72 interlock condition for On control.
DPOS01 interlock condition for Off control.
DPOS02 interlock condition for Off control.
DPOS03 interlock condition for Off control.
....
DPOS72 interlock condition for Off control.
- 440 -
6F2T0200 (0.15)
M/O
O
O
O
O
O
O
O
O
M/O
O
O
O
O
O
O
O
O
M/O
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GRE200 (1,2)

Advertisement

loading

This manual is also suitable for:

Gre200-1Gre200-2