Download Print this page

Toshiba GR-200 Series Instruction Manual page 15

Multi functional protection ied
Hide thumbs Also See for GR-200 Series:

Advertisement

Setup for the event recorder ............................................................................................. 629
8.2.4
Setting ................................................................................................................................ 630
8.2.5
Signal ................................................................................................................................. 630
8.2.6
Disturbance recorder ................................................................................................................ 631
Recording time and amount .............................................................................................. 631
8.3.1
Relays within disturbance recorder .................................................................................. 631
8.3.2
Maximum number for recording disturbance phenomena .............................................. 633
8.3.3
Number of analog quantities and logical signals for disturbance recorder .................... 633
8.3.4
Trigger settings for PLC programming ............................................................................ 636
8.3.5
Screen information ............................................................................................................ 636
8.3.6
Setting ................................................................................................................................ 638
8.3.7
Signal ................................................................................................................................. 639
8.3.8
Transferred information during fault ...................................................................................... 640
Transferred metering values ............................................................................................. 640
8.4.1
Transferred information about tripped phase and mode ................................................. 641
8.4.2
Transferred state information ........................................................................................... 641
8.4.3
Transferring record value and information ...................................................................... 642
8.4.4
9
Monitoring function ......................................................................................................................... 653
Outline ...................................................................................................................................... 654
Metering data (Metering group) .............................................................................................. 654
Metering information on the screen ................................................................................. 654
9.2.1
Setting for measurements ................................................................................................. 655
9.2.2
Diminishing a very small value to display zero ............................................................... 656
9.2.3
Flow settings for active/reactive/apparent powers........................................................... 656
9.2.4
Polarity setting for power factor values ........................................................................... 657
9.2.5
Setting for the report (Dead band feature) ....................................................................... 659
9.2.6
Statistics data (Power value group) ......................................................................................... 661
Power information on the screen ...................................................................................... 661
9.3.1
Setting for power values .................................................................................................... 661
9.3.2
Regulation of power values ............................................................................................... 661
9.3.3
Statistics data (Demand value group) ..................................................................................... 662
Demand information on the screen .................................................................................. 662
9.4.1
Max/Min/Averaged information about the demand feature ............................................ 663
9.4.2
Demand cycle ..................................................................................................................... 663
9.4.3
Resetting data in demand features ................................................................................... 664
9.4.4
Statistics data (Peak-demand value group) ............................................................................ 665
Max/Min/Averaged information about the peak-demand feature ................................... 665
9.5.1
Resetting data of peak-demand features .......................................................................... 665
9.5.2
Statistics data (Counter group) ................................................................................................ 666
xv
6F2T0200 (0.15)

Advertisement

loading

This manual is also suitable for:

Gre200-1Gre200-2