MV-BIO1
(iii)
MV-BIO1 has 8 binary output and 8 binary input circuits.
The output circuits are made of normal type and the input
circuits are made of common-negative terminal type. It
will be used for IO#2 and IO#3. The user can select a pick-
up threshold among three thresholds, which will be set for
all binary input circuits.
- 535 -
6F2T0200 (0.15)
MV-BIO1
1
BO1
2
3
BO2
4
5
BO3
6
7
BO4
8
9
BO5
10
11
BO6
12
13
BO7
14
15
BO8
16
(+)
17
BI1
(+)
18
BI2
(+)
19
BI3
(+)
20
BI4
(+)
21
BI5
(+)
22
BI6
(+)
23
BI7
(+)
24
BI8
(-) 26
Figure 5.6-3 MV-BIO1