Download Print this page

Toshiba GR-200 Series Instruction Manual page 108

Multi functional protection ied
Hide thumbs Also See for GR-200 Series:

Advertisement

Signal
2.4.10
Signal monitoring point
SEF_MV (Function ID: 442081)
Element ID
8400001B61
8100011B61
8100021B61
8100011B67
8100031B61
8100041B61
8500001B62
8200011B62
8200021B62
8200031B62
8200041B62
8000011C60
8000011C61
8100021C60
8100021C61
8200031C60
8200031C61
8300041C60
8300041C61
8000011A60
8000011A61
8000011B63
8000011B64
8000011B60
8000011C23
8000011C27
8000011B65
8000021A60
8000021A61
8100021B63
8100021B64
8100021B60
8100021C23
8100021C27
8000031A60
8000031A61
8200031B63
8200031B64
8200031B60
8200031C23
8200031C27
8000041A60
8000041A61
Name
SEF-OPT-ALARM
SEF1-OPT-ALARM
SEF2-OPT-ALARM
SEF1S2-OPT-ALARM
SEF3-OPT-ALARM
SEF4-OPT-ALARM
SEF-ARC-BLOCK
SEF1-ARC-BLOCK
SEF2-ARC-BLOCK
SEF3-ARC-BLOCK
SEF4-ARC-BLOCK
RP1F
RP1R
RP2F
RP2R
RP3F
RP3R
RP4F
RP4R
SEF1-DEF
SEF1-DEP
SEF1_BLOCK
SEF1_INST_OP
SEF1-OPT
SEF1
SEF1PU
SEF1S2-OPT
SEF2-DEF
SEF2-DEP
SEF2_BLOCK
SEF2_INST_OP
SEF2-OPT
SEF2
SEF2PU
SEF3-DEF
SEF3-DEP
SEF3_BLOCK
SEF3_INST_OP
SEF3-OPT
SEF3
SEF3PU
SEF4-DEF
SEF4-DEP
- 89 -
Description
Alarm signal by SEF protection
Alarm signal by SEF1 protection
Alarm signal by SEF2 protection
Alarm signal by SEF2 stage2 protection
Alarm signal by SEF3 protection
Alarm signal by SEF4 protection
Autoreclose block signal by SEF protection
Autoreclose block signal by SEF1 protection
Autoreclose block signal by SEF2 protection
Autoreclose block signal by SEF3 protection
Autoreclose block signal by SEF4 protection
RP1F relay element operated
RP1R relay element operated
RP2F relay element operated
RP2R relay element operated
RP3F relay element operated
RP3R relay element operated
RP4F relay element operated
RP4R relay element operated
SEF1 def output
SEF1 dep output
SEF1 protection block command
SEF1 protection instant operation command
SEF1 protection operated
SEF1 relay element operated
SEF1 relay operation level pick up
SEF1 stage2 protection operated
SEF2 def output
SEF2 dep output
SEF2 protection block command
SEF2 protection instant operation command
SEF2 protection operated
SEF2 relay element operated
SEF2 relay operation level pick up
SEF3 def output
SEF3 dep output
SEF3 protection block command
SEF3 protection instant operation command
SEF3 protection operated
SEF3 relay element operated
SEF3 relay operation level pick up
SEF4 def output
SEF4 dep output
6F2T0200 (0.15)
GRE200 (1,2)

Advertisement

loading

This manual is also suitable for:

Gre200-1Gre200-2