Setting
2.5.7
OCN_MV (Function ID:443081)
Setting items
OCN1-EN
OCN2-EN
OCN3-EN
OCN4-EN
OCN1
OCN1-Dir
Fwd/
OCN1-Angle
Rev
OCN1-Vpol
OCN1-Timer
DT
OCN1
OCN1-DPR
TOCN1
IEC
OCN1
OCN1-DPR
OCN1-TMS-
IEC
TOCN1R
UK
OCN1
OCN1-DPR
OCN1-TMS-
UK
TOCN1R
IEEE
OCN1
OCN1-DPR
OCN1-TMS-
IEEE
OCN1-Rtimer
TOCN1R
OCN1-RTMS-
IEEE
US
OCN1
OCN1-DPR
OCN1-TMS-US
OCN1-Rtimer
TOCN1R
OCN1-RTMS-
US
ORG
OCN1
OCN1-DPR
OCN1-TMS-
ORG
OCN1-Rtimer
TOCN1R
OCN1-RTMS-
ORG
OCN1-k
OCN1-a
OCN1-c
Range
Unit
Off / On
- OCN1 protection scheme switch
Off / On
- OCN2 protection scheme switch
Off / On
- OCN3 protection scheme switch
Off / On
- OCN4 protection scheme switch
NonDir / Forward /
- OCN1 directional characteristic
Reverse
-90 - 90
deg OCN1 directional characteristic angle
0.5 - 25.0
V OCN1 polarizing voltage level
DT / IEC-NI / IEC-VI /
IEC-EI / UK-LTI /
IEEE-MI / IEEE-VI /
- OCN1 delay type
IEEE-EI / US-CO2 /
US-CO8 / Original
0.02 - 150.00
A OCN1 threshold (in DT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.00 - 300.00
s OCN1 operating delay time
0.02 - 25.00
A OCN1 threshold (in IDMT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.010 - 50.000
- OCN1 time multiplier of IEC inverse curve
0.00 - 300.00
s OCN1 definite time reset delay
0.02 - 25.00
A OCN1 threshold (in IDMT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.010 - 50.000
- OCN1 time multiplier of UK inverse curve
0.00 - 300.00
s OCN1 definite time reset delay
0.02 - 25.00
A OCN1 threshold (in IDMT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.010 - 50.000
- OCN1 time multiplier of IEEE inverse curve
DEF / DEP
- OCN1 reset delay type of IEEE
0.00 - 300.00
s OCN1 definite time reset delay
OCN1 dependent reset time multiplier of
0.010 - 50.000
-
IEEE inverse curve
0.02 - 25.00
A OCN1 threshold (in IDMT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.010 - 50.000
- OCN1 time multiplier of US inverse curve
DEF / DEP
- OCN1 reset delay type of US
0.00 - 300.00
s OCN1 definite time reset delay
OCN1 dependent reset time multiplier of US
0.010 - 50.000
-
inverse curve
0.02 - 25.00
A OCN1 threshold (in IDMT mode)
10 - 100
% OCN1 drop-out/pick-up ratio
0.010 - 50.000
- OCN1 time multiplier of US inverse curve
DEF / DEP
- OCN1 reset delay type of ORG
0.00 - 300.00
s OCN1 definite time reset delay
OCN1 dependent reset time multiplier of ORG
0.010 - 50.000
-
inverse curve
0.00000 - 500.00000
- OCN1 user original curve coefficient
0.00000 - 10.00000
- OCN1 user original curve coefficient
0.00000 - 10.00000
- OCN1 user original curve coefficient
- 102 -
Contents
6F2T0200 (0.15)
Default
Note
Off
Off
Off
Off
NonDir
-45
3.0
DT
0.40
100
1.00
0.40
100
1.000
0.00
0.40
100
1.000
0.00
0.40
100
1.000
DEF
0.00
1.000
0.40
100
1.000
DEF
0.00
1.000
0.40
100
1.000
DEF
0.00
1.000
0.00000
0.00000
0.00000