Toshiba GR-200 Series Instruction Manual page 192

Multi functional protection ied
Hide thumbs Also See for GR-200 Series:

Advertisement

Setting
2.15.6
Setting of OV_MV (Function ID: 460181)
Setting device
OV1-EN
OV2-EN
OV3-EN
OV4-EN
OV1
OV1-Timer
DT
OV1
TOV1
OV1-DPR
IDMT
OV1
OV1-DPR
OV1-TMS
TOV1R
ORG
OV1
OV1-DPR
OV1-TMS
TOV1R
Output
OV1-VTFBlk
OV1-UseFor
OV2
OV2-Timer
DT
OV2
TOV2
OV2-DPR
IDMT
OV2
OV2-DPR
OV2-TMS
TOV2R
ORG
OV2
OV2-DPR
OV2-TMS
TOV2R
Output
OV2-VTFBlk
OV2-UseFor
OV3
OV3-Timer
DT
OV3
TOV3
OV3-DPR
IDMT
OV3
OV3-DPR
OV3-TMS
TOV3R
ORG
OV3
OV3-DPR
OV3-TMS
TOV3R
Output
OV3-VTFBlk
OV3-UseFor
OV4
OV4-Timer
DT
OV4
TOV4
OV4-DPR
IDMT
OV4
Range
Unit
Off / On
- OV1 protection scheme switch
Off / On
- OV2 protection scheme switch
Off / On
- OV3 protection scheme switch
Off / On
- OV4 protection scheme switch
DT / IDMT / Original
- OV1 delay type
1.0 - 220.0
V OV1 threshold
0.00 - 300.00
s OV1 operating delay time (in DT mode)
10 - 100
% OV1 drop-out/pick-up ratio
1.0 - 220.0
V OV1 threshold
10 - 100
% OV1 drop-out/pick-up ratio
0.010 - 100.000
- OV1 time multiplier (in IDMT mode)
0.0 - 300.0
s OV1 definite time reset delay
1.0 - 220.0
V OV1 threshold
10 - 100
% OV1 drop-out/pick-up ratio
0.010 - 100.000
- OV1 time multiplier (in ORG mode)
0.0 - 300.0
s OV1 definite time reset delay
Non / Block
- OV1 operation block by VTF
Trip / Alarm
- OV1 used for trip or alarm
DT / IDMT / Original
- OV2 delay type
1.0 - 220.0
V OV2 threshold
0.00 - 300.00
s OV2 operating delay time (in DT mode)
10 - 100
% OV2 drop-out/pick-up ratio
1.0 - 220.0
V OV2 threshold
10 - 100
% OV2 drop-out/pick-up ratio
0.010 - 100.000
- OV2 time multiplier (in IDMT mode)
0.0 - 300.0
s OV2 definite time reset delay
1.0 - 220.0
V OV2 threshold
10 - 100
% OV2 drop-out/pick-up ratio
0.010 - 100.000
- OV2 time multiplier (in ORG mode)
0.0 - 300.0
s OV2 definite time reset delay
Non / Block
- OV2 operation block by VTF
Trip / Alarm
- OV2 used for trip or alarm
DT / IDMT / Original
- OV3 delay type
1.0 - 220.0
V OV3 threshold
0.00 - 300.00
s OV3 operating delay time (in DT mode)
10 - 100
% OV3 drop-out/pick-up ratio
1.0 - 220.0
V OV3 threshold
10 - 100
% OV3 drop-out/pick-up ratio
0.010 - 100.000
- OV3 time multiplier (in IDMT mode)
0.0 - 300.0
s OV3 definite time reset delay
1.0 - 220.0
V OV3 threshold
10 - 100
% OV3 drop-out/pick-up ratio
0.010 - 100.000
- OV3 time multiplier (in ORG mode)
0.0 - 300.0
s OV3 definite time reset delay
Non / Block
- OV3 operation block by VTF
Trip / Alarm
- OV3 used for trip or alarm
DT / IDMT / Original
- OV4 delay type
1.0 - 220.0
V OV4 threshold
0.00 - 300.00
s OV4 operating delay time (in DT mode)
10 - 100
% OV4 drop-out/pick-up ratio
1.0 - 220.0
V OV4 threshold
- 173 -
Contents
6F2T0200 (0.15)
Default
Note
Off
Off
Off
Off
DT
120.0
1.00
100
120.0
100
1.000
0.0
120.0
100
1.000
0.0
Non
Trip
DT
120.0
1.00
100
120.0
100
1.000
0.0
120.0
100
1.000
0.0
Non
Trip
DT
120.0
1.00
100
120.0
100
1.000
0.0
120.0
100
1.000
0.0
Non
Trip
DT
120.0
1.00
100
120.0
GRE200 (1,2)

Advertisement

loading

This manual is also suitable for:

Gre200-1Gre200-2