Download Print this page

Toshiba TLCS-900/H1 Series Manual page 192

Original cmos 32-bit microcontroller
Hide thumbs Also See for TLCS-900/H1 Series:

Advertisement

SIRCR
Bit symbol
PLSEL
(1207H)
Read/Write
Reset State
Function
Select
transmit
pulse width
0: 3/16
1: 1/16
7
6
5
RXSEL
TXEN
0
0
0
Receive
Transmit
data
0: Disable
0: "H" pulse
1: Enable
1: "L" pulse
Figure 3.9.27 IrDA Control Register
92CH21-190
4
3
RXEN
SIRWD3
SIRWD2
R/W
0
0
Receive
Select receive pulse width
Set effective pulse width to equal to or more than 2x ×
0: Disable
(value + 1) + 100 ns
1: Enable
Can be set: 1 to 14
Cannot be set: 0, 15
Select receive pulse width
Formula: Effective pulse width ≥ 2x × (value + 1) + 100 ns
x = 1/f
SYS
0000
Cannot be set
Equal to or more than 4x + 100 ns
0001
to
1110
Equal to or more than 30x + 100 ns
1111
Cannot be set
Receive operation
0
Disable (Received input is ignored)
1
Enable
Transmit operation
0
Disable (Input from SIO is ignored)
1
Enable
Select transmit pulse width
0
3/16
1
1/16
Note:
If a pulse width complying with IrDA1.0 standard (1.6
μs min.) can be guaranteed with a low baud rate,
setting this bit to "1" will result in reduced power
dissipation.
TMP92CH21
2
1
0
SIRWD1
SIRWD0
0
0
0
2009-06-19

Advertisement

loading

This manual is also suitable for:

Tmp92ch21fgJtmp92ch21