R/W
ACKE
R
ACKD
Notes
Remark
www.DataSheet4U.com
CHAPTER 16 SERIAL INTERFACE CHANNEL 0 ( µ PD78014Y Subseries)
Acknowledge Signal Automatic Output Control
0
Disables acknowledge signal automatic output. (However, output with ACKT enable)
Use for reception when 8-clock wait mode is selected or for transmission
1
Enables acknowledge signal automatic output.
Outputs acknowledge signal in synchronization with the 9th clock falling edge of SCL (automatically output
when ACKE = 1). However, not automatically cleared to 0 after acknowledge signal output.
Used in reception with 9-clock wait mode selected.
Acknowledge Detection
Clear Conditions (ACKD = 0)
• Upon execution of a transfer start instruction in the I
mode
• When CSIE0 = 0
• When RESET input is applied
1. Should be set before starting transfer.
2. Output acknowledge signal in reception with ACKT when 8-clock wait is selected.
CSIE0: Bit 7 of the serial operating mode register 0 (CSIM0)
Note 1
2
(in the I
C bus mode)
Note 2
Set Conditions (ACKD = 1)
2
C
• When acknowledge signal is detected at the rising
edge of SCL clock after completion of transfer
.