15.2.2.19 Timer 2 Capture Registers

There are two CAP(n) Registers for Timer 2. They are designated:
• CAP0
• CAP1
Each register is a 16-bit, Read Only register. When a capture condition occurs, the con-
tents of the counter CNT are stored into the associated Capture Register. Capture Regis-
ters correspond to the input signals CTCAP2A through CTCAP2B, respectively. The edge
of the input signal used to trigger the capturing operation is determined by setting the
CTRL Register.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR

Table 15-40. CAP(n) Register

31
30
29
28
27
0
0
0
0
0
R
R
R
R
R
15
14
13
12
11
0
0
0
0
0
R
R
R
R
R

Table 15-41. CAP(n) Register Definitions

BITS FIELD NAME
31:16
///
15:0
CAP2
26
25
24
23
///
0
0
0
0
R
R
R
R
10
9
8
7
CAP2
0
0
0
0
R
R
R
R
CAP0: xFFFC4000 + 0x68
CAP1: xFFFC4000 + 0x6C
DESCRIPTION
Reserved Read as zero.
Timer 2 Capture 16-bit Capture Register Value.
6/17/03
22
21
20
19
18
0
0
0
0
0
R
R
R
R
R
6
5
4
3
2
0
0
0
0
0
R
R
R
R
R
Timers
17
16
0
0
R
R
1
0
0
0
R
R
15-31