Configuring A Line Module; Enabling/Disabling Controlled Bypass For M12 Line Modules - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

RUGGEDCOM ROX II
CLI User Guide
SLOT
MODULE TYPE
-------------------------------------------------------------------
sm
SM 88 Gigabit Layer 3 w/ 2x 10G SFP+ slots
lm1
4x 10/100/1000TX RJ45
lm2
none
lm3
none
lm4
16x 10/100TX RJ45
lm5
16x 10/100TX RJ45
lm6
16x 10/100TX RJ45
!
!
If no line modules have been configured, install line module as needed. For more information, refer to
Section 3.15.2, "Installing a New Line
Section 3.15.4

Configuring a Line Module

To configure a line module, do the following:
1.
Make sure the CLI is in Configuration mode.
Navigate to chassis » line-modules » line-module » {module}, where {module} is the line module.
2.
3.
Configure the following parameter(s) as required:
Parameter
detected-module
module-type { module-type }
admin-enabled
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.15.5

Enabling/Disabling Controlled Bypass for M12 Line Modules

Controlled bypass is used to allow Ethernet traffic to bypass a defective unit in a network chain while preventing
the loss of data.
Figure 3: Sample Controlled Bypass Diagram
1. Ethernet Traffic Generator
Configuring a Line Module
Module".
1
2
2. Router 1
3. Defective Router with M12 Bypass Control
ENABLED
BYPASS
X
-
X
-
-
-
-
-
X
-
X
-
X
-
Description
Synopsis: A string 1 to 60 characters long
The installed module's type specifier.
Sets the module type to be used in this slot.
Synopsis: typeless
Sets the administrative state for a module. Enabling the module
powers it on.
3
4
5
4. Router 2
Chapter 3
Device Management
5. Ethernet Traffic Receiver